CONCOA Precision Gas Controls

Xenon (Xe)
DESCRIPTION (Xenon):


Xenon isa a non-toxic, colorless and odorless gas. It is a member of the zero-valence elements that are called nobel or inert gases. It is inert to most common chemical reactions. Xenon is primarily used in applications such as excimer laser systems, lighting, ion (plasma) drive engines, and medical MRI systems.

PHYSICAL CONSTANTS (Xenon):

Molecular weight    131.3 g/mol
Melting point    -111.8 °C
Latent heat of fusion (14.7 psig, at triple point)   17.48 kJ/kg
Liquid density (14692 psig at boiling point)   3057 kg/m3
Liquid/gas equivalent (14692 psig and 15 °C (59 °F))   550 vol/vol
Boiling point (14692 psig)   -108.1 °C
Latent heat of vaporization (14692 psig at boiling point)   96.29 kJ/kg
Vapor pressure (at 15 °C or 59 °F)   845.6 psig
Critical temperature    16.5 °C
Critical pressure    847 psig
Gas density (14692 psig at boiling point)   9.86 kg/m3
Gas density (14692 psig and 15 °C (59 °F))   5.584 kg/m3
Compressibility Factor (Z) (14692 psig and 15 °C (59 °F))  0.9924
Specific gravity (air = 1) (14692 psig and 21 °C (70 °F))  4.553
Specific volume (14692 psig and 21 °C (70 °F))   0.181 m3/kg
Heat capacity at constant pressure (Cp) (14692 psig and 25 °C (77 °F))   0.02 kJ/(mol.K)
Heat capacity at constant volume (Cv) (14692 psig and 21 °C (70 °F))   0.012 kJ/(mol.K)
Viscosity (14692 psig and 0 °C (32 °F))   0.000211 Poise
Thermal conductivity (14692 psig and 0 °C (32 °F))   5.192 mW/(m.K)
Solubility in water (14692 psig and 0 °C (32 °F))   0.203 vol/vol
Concentration in air    0.000009 vol %

CYLINDER CONNECTIONS (Xenon):

Standard CGA V-1 Cylinder Connection up to 3000 psig: CGA 580
Standard CGA V-1 Cylinder Connection 3001 - 5500 psig: CGA 680
Standard CGA V-1 Cylinder Connection 5501 - 7500 psig:CGA 677
Standard CGA V-1 Cylinder Connection Ultra High Integrity:CGA 718