Intrinsic Safety Barrier for Pressure Switch Gauges

Intrinsic safety barrier for use with pressure switch gauges
5295312 shown

The Intrinsic Safety Barrier is an essential isolation device that ensures the safe use of electrical equipment with pressure switch gauges when using flammable gases or in hazardous environments. CONCOA single and dual-channel intrinsic safety barriers control the power source and keep electrical circuit energy below minimum ignition levels. By protecting against power surges and reducing the risk of ignition where potentially explosive gases are used, the CONCOA intrinsic safety barrier for pressure switch gauges protects both workers and the facility. Please note that intrinsic safety barriers have been validated only with CONCOA pressure switch gauges and remote alarms, monitors, and controllers. This model is not intended for use with CONCOA pressure transducers.

  • Protective circuit prevents tripping of both fuses at the same time
  • Durable polyamide enclosure resists impact and wear even in harsh environments
  • Replaceable backup fuse provides protection for each channel
  • Single and dual channel intrinsic safety barriers include 4 inch mounting rail and adapter
  • Current limitation: Resistive; Replaceable fuse protection for each channel
  • Dimensions: 4.090 in w x 0.48 in l x 2.76 in d (103 mm x 12 mm x 70.1 mm)
  • Temperature range: -4°F to 140°F (-20°C to 60°C)
  • Potential channel 1: Positive
  • Grounding method: Designated ground electrode with #12 AWG size conductor or larger (Ground path resistance not to exceed 1 ohm)
  • Mounting location: Class I, Div. 2 non-hazardous
  • Weight: 0.24 lb (0.110 kg)
  • Conformances: UL approved
◂ scroll to see more ▸ 
Part Number Description
5295296 Single-Channel Intrinsic Safety Barrier for Products Using Pressure Switch Gauges, Max Voltage DC 15.80v
5295312 Dual-channel Intrinsic Safety Barrier for Products Using Pressure Switch Gauges and with Altos 2™ Alarm, Max Voltage DC 28v
◂ scroll to see more ▸ 
Document
Language
ID Number
Revision
Intrinsic Safety Barriers Catalog Page
English
INISB
M
AutoSwitch Systems with Pressure Switch Gauges Installation and Operation
English
ADI3209
11
Schematic for Dual Regulator Switchover with Pressure Switch Gauges
English
ADI3238
3

WARNING: This product can expose you to chemicals including Lead, Chromium, Nickel, and 1-3 Butadiene, which are known to the state of California to cause cancer, birth defects, or other reproductive harm. And, this product can expose you to chemicals including Bisphenol A (BPA) which is known to the State of California to cause female reproductive harm. For more information go to www. PSWarnings.ca.gov.