Skip to main content
page top
See all in Gas Safety Equipment

580 Series UV/IR Flame Detector

Ultraviolet and Infrared flame detector for hydrocarbon and non-hydrocarbon fires
580 5005 shown

The 580 Series UV/IR Flame Detector utilizes dual-spectrum sensors to provide high-speed fire detection with exceptional false alarm immunity. By combining ultraviolet (UV) and infrared (IR) optical sensors, the device identifies both hydrocarbon and non-hydrocarbon fires within seconds and triggers an immediate response. Engineered for reliability, the 580 Series UV/IR Detector is resistant to the influences of direct or reflected sunlight and artificial lighting (florescent/halogen), electrical arcs and static discharges, and the radiation from arc welding (at distances exceeding 10 feet). Whether used as a standalone device or integrated into a networked safety system, the 580 Series UV/IR Flame Detector provides a dependable foundation for any fire monitoring solution.

  • Dual spectrum technology utilizes UV and IR sensors for high-accuracy detection and superior false alarm immunity
  • Broad range detection provides extensive area coverage
  • Rapid alarm response enables quick safety and suppression actions
  • Continuous internal health monitoring prevents undetected device failure
  • Durable GRP fiberglass construction offers exceptional chemical, UV, and corrosion resistance
  • Manual remote self-test facilitates functional sensor verification from a remote location without a test lamp
  • Pressure compensating element (PCE) eliminates internal moisture build-up and protects internal seals from ambient pressure changes
  • Configurable alarm relay accommodates specific site requirements
  • Hazardous area certification supports use in harsh indoor and outdoor environments
  • Flexible output options allow universal system integration through both 0–20 mA analog and SPDT relay signals
  • Optional swivel mount (included) permits installation flexibility and precise directional positioning
  • Sensor Type: Dual ultraviolet (UV) and infrared (IR) sensors
  • Field of View: 90° minimum cone of vision
  • Detection range: 75 ft (23 m) for a 1 ft2 (0.1 m2) n-heptane pan fire
  • Spectral sensitivity: 4.2 - 4.6 microns (IR); 180 - 250 nm (UV)
  • Power requirements: 10–28 VDC (12–24 VDC nominal), 25 mA normal operating current
  • Response time: 8 - 30 seconds
  • Operating temperature: -13°F to 158°F (-25°C to 70°C)
  • Analog output: 0-20 mA (stepped, sinking, non-isolated)
  • Relay Outputs: One configurable latching/non-latching alarm relay (normally de-energized) and one fault relay (normally energized), Form C (SPDT) 2A @ 30 VDC rated
  • Enclosure: Fiberglass (glass reinforced polyester/GRP) UV resistant, self-extinguishing V-0 (UL-94)
  • Swivel mount: Nylon (polyamide/PA66) with stainless steel hardware
  • Conformances (enclosure): IP65; FM Class 1, 2 & 3 Div 2 and ATEX Zone 2/22
◂ scroll to see more ▸ 
Part NumberDescription
5805005-01-1 580 Series UV/IR Flame Detector/Transmitter with swivel mount
◂ scroll to see more ▸ 
Document
Language
ID Number
Revision
580 Series UV/IR Flame Detector Catalog Page
English
RSUVIRDET
AH
CONCOA Safe Handling of Flammable Gases in Laboratories Brochure
English
SPF650
C

general warning action yellow triangle with exclamationWARNING: This product can expose you to chemicals including Lead, Chromium, Nickel, and 1-3 Butadiene, which are known to the state of California to cause cancer, birth defects, or other reproductive harm. And, this product can expose you to chemicals including Bisphenol A (BPA) which is known to the State of California to cause female reproductive harm. For more information go to www. PSWarnings.ca.gov.